Recent content by jmwang

  1. jmwang

    Important!!IVS failed and Triangle warnning issue Solutions for 4MP AI models

    Couple questions Andy- 1) If I just maintain my setup (0521 firmware which is working) and upgrade when the next firmware becomes available can I avoid doing what you mentioned. I have a few cameras that have this issue, and the cameras work pretty well as they are. 2) Also, I have a 5241...
  2. jmwang

    4.0 AI New models General_IPC-HX5XXX-Volt_Eng_PN_Stream3_V2.800.0000000.1.R.190706.zip

    the initial link expired I believe. I think the one andy reposted under this heading will work. AI 4.0 latest new firmware DH_IPC-HX5XXX-Volt_MultiLang_PN_Stream3_V2.800.0000000.0.R.190521.zip
  3. jmwang

    IPC-T5442TM-AS Auto IR bug fixed firmware 20190930

    I tried pretty much all the suggestions at some point trying to make this work, but the 0521 version seemed to be the one that worked for me (on the cameras that gave the license expiration error. I do have 4/7 cameras which seem to be working well the with 0930 version).
  4. jmwang

    IPC-T5442TM-AS Auto IR bug fixed firmware 20190930

    I can now confirm betogar's problem. After having 1 IPC-T5442TM-AS work really well and ordering 5 more, I started to set them up. I setup 1 more camera- so far so good. With my process down, I setup 2 more simultaneously (different IP's obviously). One camera is giving me the algorithm version...
  5. jmwang

    IPC-T5442TM-AS Auto IR bug fixed firmware 20190930

    Interestingly the 0930 worked well for me on this camera. I didn't even factory reset and it worked great. I had the same problem on my 5241-AS-PV with the 0706 however, and am having to use the old firmware. (all FW appropriate for that camera) If betogar or I are making some configuration...
  6. jmwang

    4.0 AI New models General_IPC-HX5XXX-Volt_Eng_PN_Stream3_V2.800.0000000.1.R.190706.zip

    Hi Andy, I downgraded the firmware on my newly bought IPC-T5241H-AS-PV from 0706 to 0521 and IVS now works reasonably well. Its not nearly as reliable as on 5442 (release date 0930) but at least it isn't COMPLETELY broken like on the 0706 version. Be happy to test out this new firmware for you.
  7. jmwang

    4.0 AI New models General_IPC-HX5XXX-Volt_Eng_PN_Stream3_V2.800.0000000.1.R.190706.zip

    Hi Andy- Are you sure this doesn't affect anything? I have this error, and coincidentally I *cannot* get IVS intrusion or tripwire to work. I've gotten it to work nicely on 3 other cameras that I bought from you.