I have no errors in the Blue Iris Tools but the CPU usage starts low and gradually increases to ~25% until the app is restarted. Weather update frequency is 15 mins. Watchdog function is disabled; updates disabled. Any other way to address this?
Hi - may I ask if or how you finally resolved this? Am experiencing something similar. Have disabled Settings > Cameras > Hardware accelerated decode = No (was Yes) and my CPU utilization still seems OK. Only it's much more sporadic now. Was previously about 7-10%. Is now about 15-20% and...
BIT 1.6.0 Weather Overlay tab is the only tab in BIT I can access. It is successfully updating weather at the specified internal. However I'm unable to click on Watchdog, Web Server Files or Options tab. Nothing happens.
How do you keep the weather overlay populated always? It seems like the CPU% remains constantly but weather is only displayed periodically. It should be there always and only update at defined intervals.
Unfortunately I cannot even login to the MyCommerce site to update any of my information. It asks if I want to reset credentials or to get emails for my most previous orders. I then get several emails, none permit me to login. It's a mess.
Since updating to the latest BI 5.2.5.2 x64 I've noticed stunnel has stopped working. BI5 runs fine. Stunnel seems to run OK, but am unable to make an incoming connection from internet to BI5 over stunnel and no firewall config changes have been made.
Correct. If you follow my instructions, it will overcome those errors. Have been there, faced all variations, until I figured it out. Steps posted above.
Post your stunnel error log. Will see whether we can help. I spent several hours trying all sorts of combinations before I was able to get it to work on iOS 13.4. Turned out that step #3 was the critical and, in my case, accidental.
Yes, confirming the iOS issue was definitely due to changes in the new iOS 13.4 update. That's also when my issue began.
Either way, was also able to troubleshoot the issue with ZeroSSL (above) after much tedious trial and error. The fix was:
1.) you can edit the stunnel.pem file in Notepad++...
Unfortunately I've tried these steps. However when I launch stunnel GUI, it attempts to load my stunnel.pem but returns the following error:
[ ] Running on Windows 6.2
[ ] No limit detected for the number of clients
[.] stunnel 5.56 on x64-pc-mingw32-gnu platform
[.] Compiled/running with...
If I would prefer, when manually triggering my CONTINUOUS profile, to not parse the video clip into pieces, how would you suggest I set these parameters? Thank you again for your guidance.
Understood. For my CONTINUOUS record camera profile, the RECORD > OPTIONS values are set as follows:
- Pre-trigger buffer: 5.0 sec
- Combine or cut video each: 8 hrs, 0 mins, 4.5 GB
- Cut video when triggered with break time: 30 sec