I've run into this issue only from LAN, I think i just solved it, in my case I had the login issue intermittently only in my home. In my case I had bad DNS setup at home.
In the blue-iris app i have configured
LAN as http://lan_ip:81
WAN as https://domain.duckdns.org from WAN...
Hi @freefaller85
i've been away from this site for a couple of weeks, just curious what worked, was your docker in windows configured platform windows? or did you use the entire docker command line which has some advantages over the gui?
1 more trick you can try . click Windows key then type -> Windows Defender with Advanced Security
then click on->Inbound Rules
you'll see somewhere in inbound rules 2 com.docker.backend
1 is for tcp
1 is for udp
double click on the row for tcp
General tab-> change action...
Try starting docker with Network in Bridge mode. In Bridge mode the port 80 will be listened not just at your 192.168.xxx.xxx machine ip, but also 127.0.0.1 if you are running AITool on the same
machine, if your issue is W10 firewall, maybe the firewall wont block if your Deepstack url...
This may be nothing, but in windows docker,it runs in 2 modes linux platform or windows platform, I'm running my deepstack docker in linux platform. I've never tried it running in windows platform, don't know if it would run perfectly or run with errors in windows platform.
if you are...
I've seen that time to time, that's why in my camera settings->Record->Options
i've checked the box Pre-trigger video buffer 30 sec.
the 30 sec video before trigger only works if you have Continuous recording, maybe a few other ones, but not just "When triggered"
I don't know much about the inner workings of the code, but not much clue to go on, without error message.
can you open a command prompt cmd.exe change directory to the Aitool release folder and launch from command aitool.exe
maybe it'll give a message that's not seen in popup gui.
Do...
There are some perks if you use AI clone camera and the original.
In the AI camera where I can have a lot of false positives, I don't set any Alert actions (on Alert, or on Reset).
The Original camera is triggered by AITool after it meets confidence criteria ,
So I have higher confidence...
have you tried blue Iris->settings->Web Server->Advanced->
uncheck "Use secure session keys and login page"
the Limit IP Addresses:-> ^127.0.0.1 or +127.0.0.1
is no longer working don't know how long its been broken.
in Blue Iris 5.2.9.2 passing password is now giving authentication required error message,
in Blue Iris 5.2.7.12 passing password still works.
in both Blue Iris branches , if you've setup authentication required from Non-Lan Only and were using
+, ^ to bypass the basic firewall function...
edit:
looks like 3 of my camera files in camera's folder were corrupt, they had nothing but null characters only. I had to remove them
and recreate the camera setups from scratch. Plus with the new blue Iris bug I had to add &user=username&pw=password to the all the camera...
Could you be having antivirus software issue?
if you don't have antivirus installed you might need to create an inbound rule in Windows Defender Firewall and Advanced Security. I've added a rule for program "C:\Program Files\Blue Iris 5\BlueIris.exe" for any protocol, which allows any port...
Yes 10sec, i'm starting to think I have a buggy version of Blue Iris. my version 5.0.7.2 x64.
I just bought this, so I haven't found a release that is working great yet.
even trying to trigger by Global DIO Input bits is very inconsistent behavior on my release
using the url...
Hi,
thanks for the great tool, and instructions. I've setup so far 4 cameras with 4 clones similar to post 219 on page 11 in this forum.
only thing I've noticed that I haven't been able to resolve is after the AI Tool sends a trigger via url to the original camera with motion detection...