I'm going to suggest something that may sound way too simplistic so please don't take offense, but just so you/we don't miss the obvious, make sure your power supply (presumably PoE) and cabling are not having any issues. I once experienced a similar reboot problem with an early version of this model and just coincidentally while debugging plugged into a different PoE++ port (instead of the original PoE+ port) and "magically" the reboot stopped. I still don't know whether the original PoE+ port degraded, or the camera itself with age needed more power, but after several years of use I had reboot problems which "more power" seemed to address.
thanks for your answer, All the time I have used a 12V at 3A power supply I don't know if I can interpret that the camera has damaged firmware.
- When connecting the power source to the camera, the Ethernet LEDs work after 5 seconds but after another 10 seconds they turn off and restart in a loop. (When I ping the IP address 192.168.1.108 I have a response but then it disappears)
Request timed out.
Reply from 192.168.1.70: Destination host unreachable.
Reply from 192.168.1.70: Destination host unreachable.
Reply from 192.168.1.70: Destination host unreachable.
Reply from 192.168.1.70: Destination host unreachable.
Request timed out.
Request timed out.
Reply from 192.168.1.108: bytes=32 time=6ms TTL=128
Reply from 192.168.1.108: bytes=32 time=8ms TTL=128
Reply from 192.168.1.108: bytes=32 time=8ms TTL=128