VCA Target Highlight does not exist on playback or live view
Minimum (5 seconds) or maximum possible pre-record (30 seconds) on camera do not work. Auto Event playback starts 5 to 10 seconds after the target is gone on any resolution or bit rate for DS-2CD2047G2-L ColorVu. No option to manually...
Same problem here on 2022 NVR model:
DS-2CD2047G2-L connected on DS-7608NXI-K2 Event Playback starts 5 to 10 seconds after the target is gone!!!!! (1920x1080, variable bitrate, 3072kbps, 25fps)
On iVMS-4200 Event Playback works exactly as you set pre-record and post-record. On NVR playback...
Thank you this worked for me. Saved my DS-KV6113-WPE1 from continuing reboot after selecting Semi-Digital mode.
Now I have also a new one since I had not seen your method before ordering a new one.
New one has a new firmware that I cannot find on any server( V2.1.3 build 191113). The old one is...
DS-KV6113-WPE1
Infra Red is faulty. First two days it was OK. Possible Firmware problem or Voltage problem(needs more than 12V DC ?). Infra Red IR is not enabled. The only way to enable is during day light, put a thick black cloth on lens and the moment that Day/Night mode changes to Night and...