Long story short, for years been suffering with a heating zone on the 2nd floor, currently wireless thermostat, gone through 3 of them and receivers to boot. The Guy who installed it like 23 yrs ago suggested I run a hard wire up there, Been putting it off but I had a route planned.
Just drill through the vanity upstairs direct to a closet below, from the closet down to the basement. All the plumbing was behind the vanity wall, I even ask the guy if he remember where the plumbing was(same guy did the plumbing). He "THOUGHT" it was too but hey, that was a long time ago. When I hit it, there was a 30 second dash to the main shutoff, had a little water running down a chase in the basement, a bit in the closet also, got very lucky. Now I have to figure out a bet way to repair this, Im thinking a plumber should cut and re-solder it proper. I can open it up a bit more but it goes through floor joists. Best it happened in my own house than a clients, I did drill into a suction line in a dentist office once years ago but I was able to fix that one. Now that its really open I can run my wire..:angry:

OhSHIT.jpg
 

mat200

IPCT Contributor
Joined
Jan 17, 2017
Messages
13,649
Reaction score
22,738
Long story short, for years been suffering with a heating zone on the 2nd floor, currently wireless thermostat, gone through 3 of them and receivers to boot. The Guy who installed it like 23 yrs ago suggested I run a hard wire up there, Been putting it off but I had a route planned.
Just drill through the vanity upstairs direct to a closet below, from the closet down to the basement. All the plumbing was behind the vanity wall, I even ask the guy if he remember where the plumbing was(same guy did the plumbing). He "THOUGHT" it was too but hey, that was a long time ago. When I hit it, there was a 30 second dash to the main shutoff, had a little water running down a chase in the basement, a bit in the closet also, got very lucky. Now I have to figure out a bet way to repair this, Im thinking a plumber should cut and re-solder it proper. I can open it up a bit more but it goes through floor joists. Best it happened in my own house than a clients, I did drill into a suction line in a dentist office once years ago but I was able to fix that one. Now that its really open I can run my wire..:angry:

View attachment 145806
looks like this is possible ..

 

c hris527

Known around here
Joined
Oct 12, 2015
Messages
1,782
Reaction score
2,066
Location
NY
looks like this is possible ..

I like the copper patch idea, Not sure yet if I penetrated the other side of it , Its possible I weakened it, not sure if that is code either but looks pretty easy to do.
 

wittaj

IPCT Contributor
Joined
Apr 28, 2019
Messages
24,428
Reaction score
47,544
Location
USA
Go with if they sell it, it meets code LOL.
 

ptzman

Getting comfortable
Joined
Mar 25, 2019
Messages
75
Reaction score
105
Location
North carolina
What I have done is to get a piece of solid copper wire slightly larger than the hole diameter. After cleaning everything up, I work the wire into the hole, flux it, and solder it. The length of wire insert into the hole should be about the same as the thickness of the copper pipe wall. Those repairs after many years are still holding.
 

tigerwillow1

Known around here
Joined
Jul 18, 2016
Messages
3,815
Reaction score
8,424
Location
USA, Oregon
Reminds me of when I drilled a hole through the outside wall of our motorhome, thinking it was an inside wall. I went from highly confident to freaking out in an instant when I saw daylight through it. I was fortunately able to get it patched and painted before the wife noticed it.
 

c hris527

Known around here
Joined
Oct 12, 2015
Messages
1,782
Reaction score
2,066
Location
NY
What I have done is to get a piece of solid copper wire slightly larger than the hole diameter. After cleaning everything up, I work the wire into the hole, flux it, and solder it. The length of wire insert into the hole should be about the same as the thickness of the copper pipe wall. Those repairs after many years are still holding.
So I had a thin screwdriver, poked it in the hole, definitly a divitt on the bottom of that so its got to come out...grrrr
 

Smilingreen

Known around here
Joined
Sep 17, 2021
Messages
3,599
Reaction score
14,373
Location
Tennessee USA
Long story short, for years been suffering with a heating zone on the 2nd floor, currently wireless thermostat, gone through 3 of them and receivers to boot. The Guy who installed it like 23 yrs ago suggested I run a hard wire up there, Been putting it off but I had a route planned.
Just drill through the vanity upstairs direct to a closet below, from the closet down to the basement. All the plumbing was behind the vanity wall, I even ask the guy if he remember where the plumbing was(same guy did the plumbing). He "THOUGHT" it was too but hey, that was a long time ago. When I hit it, there was a 30 second dash to the main shutoff, had a little water running down a chase in the basement, a bit in the closet also, got very lucky. Now I have to figure out a bet way to repair this, Im thinking a plumber should cut and re-solder it proper. I can open it up a bit more but it goes through floor joists. Best it happened in my own house than a clients, I did drill into a suction line in a dentist office once years ago but I was able to fix that one. Now that its really open I can run my wire..:angry:

View attachment 145806
My wife did that a few years ago in out kitchen. She decided she wanted to put up some shelf bracket in the corner above the counter top. I told her to be careful, as the washing machine hookup was right on the other side of the wall in the utility room. She was careful. She perfectly centered her drill bit, right into the hot water supply for the washing machine. I was at work. Somehow, she remembered the water cutoff for the house was down underneath and she got the water turned off. I had to cut a big section of drywall out so I could cut the drilled section out and sweat a coupler on it.
 

c hris527

Known around here
Joined
Oct 12, 2015
Messages
1,782
Reaction score
2,066
Location
NY
Glad I did hit the copper
Man when my house was getting built in 2019 I took pictures of all the walls that had electrical and plumbing in them. I bet you had a REAL OH $HIT moment!
Yea It was done in like 1999, I would not even remember if I had pictures even If I did take them.
 

Flintstone61

Known around here
Joined
Feb 4, 2020
Messages
6,587
Reaction score
10,894
Location
Minnesota USA

c hris527

Known around here
Joined
Oct 12, 2015
Messages
1,782
Reaction score
2,066
Location
NY

View attachment 145821
Lots of people really like these and for sure its not out of the question, I like the brass compression fittings with brass ferrules in this area because its the top floor, The sharkbites and push on fittings have a rubber o-ring and it kind of bothers me the minerals and chorline in the water might raise hell over time. Its in a really tight spot so I might have to go that route. The pipes go through floor joists and are glued in through them so its looking like my options are limited without ripping up tile and pulling the vanity out. The good thing is that its on the draw side of the vanity so it no issue leaving it open to check on from time to time to check for leaks if I do use sharkbites.
 

Flintstone61

Known around here
Joined
Feb 4, 2020
Messages
6,587
Reaction score
10,894
Location
Minnesota USA
When we bought the house, the Garden hose Spigot was faulty outside. So we got tired of using the back yard one.
so I tried twisting/Unscrewing it from outside. It just twisted the copper.
the Water Softener is blocking access on the other side of the wall.
So the guy at Menards hooked me up with a 2 sharkbite solution. 1 is 8 inches below ( out of picture(882962AD-4472-49B5-9DD8-D9B249754E7E.jpeg32270AEE-C2DA-43BF-B8EF-51AF7B843C93.jpeg
 

TonyR

IPCT Contributor
Joined
Jul 15, 2014
Messages
16,432
Reaction score
38,152
Location
Alabama
Long story short, for years been suffering with a heating zone on the 2nd floor, currently wireless thermostat, gone through 3 of them and receivers to boot. The Guy who installed it like 23 yrs ago suggested I run a hard wire up there, Been putting it off but I had a route planned.
Just drill through the vanity upstairs direct to a closet below, from the closet down to the basement. All the plumbing was behind the vanity wall, I even ask the guy if he remember where the plumbing was(same guy did the plumbing). He "THOUGHT" it was too but hey, that was a long time ago. When I hit it, there was a 30 second dash to the main shutoff, had a little water running down a chase in the basement, a bit in the closet also, got very lucky. Now I have to figure out a bet way to repair this, Im thinking a plumber should cut and re-solder it proper. I can open it up a bit more but it goes through floor joists. Best it happened in my own house than a clients, I did drill into a suction line in a dentist office once years ago but I was able to fix that one. Now that its really open I can run my wire..:angry:

View attachment 145806
If someone had said "OK, I'll give you $5,000 if you can drill into this wall and hit a pipe dead center" you would have never collected a dime, right? :facepalm:
 