Updated NVR firmware published - NVR_78_79_EXX_V3.4.80_160718.zip

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
Hikvision have published some updated firmware for
[FONT=&amp][FONT=&amp]DS-7804/08/16N-E1DS-7804N-E1/4NDS-7804N-E1/4P、[/FONT][/FONT][FONT=&amp] DS-7808/16/32N-E2、DS-7808/16/32N-E2/8N、[/FONT][FONT=&amp]DS-7808/16/32N-E2/8P、[/FONT]
[FONT=&amp] DS-7816/32N-E2/16N、DS-7816/32N-E2/16P、[/FONT]
[FONT=&amp]DS-7908/16/32N-E4、[/FONT][FONT=&amp]DS-7908N-E4/8P、DS-7916/32N-E4/16P[/FONT]
on their CN website here : http://www1.hikvision.com/cn/download_more_699.html#prettyPhoto
NVR_78_79_EXX_V3.4.80_160718.zip
I don't see any release notes, and no equivalent yet on the Hikvision Europe site.
It might be the promised Gmail fix.
And maybe some more restrictions ... if they've been paying attention to any new exploits that have got out.
I'll maybe have a peek at it tonight.
 

jacngo

n3wb
Joined
Jul 28, 2016
Messages
27
Reaction score
2
Location
Australia
I managed to upgrade the firmware on my Hikvision DS-7608N-E2/8P (has 8 poe ports) to current version of 3.4.80 Build 160718 (18th July 2016) hehehehehe .
The firmware file I used was from China hikvision, since the DS-7608N-E2/8P is equivalent to the china version DS-7808N-Ex. I upgraded via the web method thanks to [FONT=&amp]wzhick and alairstairstevenson fanx

[/FONT]
Your posts were invaluable. I DID NOT have to use the hiktooks05R1.exe to change the language flag. Just took the plunge and uploaded the chinese firmware via the web console and wola.
I was nervous my language would be reset back to chinese but since its hacked into english already by seller, it worked fine for me.

I am happy as Larry
 
Last edited by a moderator:

jacngo

n3wb
Joined
Jul 28, 2016
Messages
27
Reaction score
2
Location
Australia
Hi Q2U,

thanks matey yes I am from down under kekekeke............................... Australia that is (^__^)
 

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
Have you spotted any differences yet - maybe some extra email configuration choices to fix the Gmail TLS requirement?
A Playback timeline on the web GUI including both motion events and continuous might be too much to hope for.
 

mayfer

n3wb
Joined
Jun 8, 2015
Messages
16
Reaction score
1
Jacngo, do you remember what software version you came from? Have you ever upgraded your NVR prior to this?
Thank you
 

Del Boy

Getting comfortable
Joined
Mar 19, 2015
Messages
2,727
Reaction score
294
Location
UK - England
Have you spotted any differences yet - maybe some extra email configuration choices to fix the Gmail TLS requirement?
A Playback timeline on the web GUI including both motion events and continuous might be too much to hope for.
There are different colours for Alarm (which seems to include motion and event) and Continuous. I'm just testing now.

No TLS available still.
 

Del Boy

Getting comfortable
Joined
Mar 19, 2015
Messages
2,727
Reaction score
294
Location
UK - England
Update: nope still solid Continuous and no highlighting of events when it does that.

Maybe I've got it setup wrong, will play a bit more but not looking promising.

Plugin version updated to v3.0.6.6. I have no idea if anything else has changed.
 

Del Boy

Getting comfortable
Joined
Mar 19, 2015
Messages
2,727
Reaction score
294
Location
UK - England
Ok I've worked it out and you can filter for motion, intrusion detection, line crossing etc. Big problem though. It doesn't work except for motion and doesn't work if you continuously record. This is despite it saving the dynamic analysis information, so it is there. One step closer I guess.

Stability all fine so far.
 

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
It would be so good to be able to have continuous recording with smart events highlighted on the web GUI playback timeline, the best of both worlds.

I'm having a look around the firmware before I actually try this on a device.
I don't want it to go and mess with the NVR bootloader, like adding the 'unrollback' (sic) check - or only accepting signed firmware.
What I do see so far, though, is a new no-rollback check in the main firmware itself.
And a couple more tripwires presumably aimed at breaking modified firmware.
 

Del Boy

Getting comfortable
Joined
Mar 19, 2015
Messages
2,727
Reaction score
294
Location
UK - England
It would be so good to be able to have continuous recording with smart events highlighted on the web GUI playback timeline, the best of both worlds.
Yes, via the monitor it allows this. It would be great via the Web GUI and I've seen it on cheaper brands so can't see why not.

I think if I ever needed to roll it back then it's going to have to go back to v3.0.8 or something crazy.

Other info would be great. Many thanks again alastair.
 

mayfer

n3wb
Joined
Jun 8, 2015
Messages
16
Reaction score
1
Is there anything in this new version that would prevent a roll back? (I always like the option to roll back to my original v3.0.8)
 

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
Is there anything in this new version that would prevent a roll back? (I always like the option to roll back to my original v3.0.8)
I haven't tested this yet - but the firmware does appear to block rolling back to earlier versions via the web GUI.
.rodata:00A18824 aSDThisDeviceCa DCB "[%s][%d]this device can not rollback to version small than 3.4.8"
 

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
That looks like a good range of additional functionality. There were no release notes on the CN site.
We don’t recommend users to upgrade DS-7608NI-I2 and DS-7608NI-I2/8P to V3.4.80 due
to RAM limit.
Strange that the older -Ex series is apparently OK, but not the newer faster bigger -I series.
And that the firmware is labelled 'K51', not 'K41'.
I wonder if they have got mixed up on this.
 

scn101

Getting the hang of it
Joined
Feb 25, 2015
Messages
193
Reaction score
55
Location
Dallas, TX
I think they did mix it up. My 7616NI-E2 won't accept the K51 file. It did accept the 3.4.62 K41 file without issues.
 

Del Boy

Getting comfortable
Joined
Mar 19, 2015
Messages
2,727
Reaction score
294
Location
UK - England
My NVR is actually 7616N-E2/8P and it worked on that.

"[Double Stream Record]I series NVR supports double stream record, user can configure video stream type in RecordParameters-MoreSettings. Please notice we don’t recommend users to use this function inDS-7608NI-Ix/xP"

I don't think this is a double mistake. Something about the DS-7608NI-I2 it seems.
 

alastairstevenson

Staff member
Joined
Oct 28, 2014
Messages
15,964
Reaction score
6,794
Location
Scotland
@Del Boy Questions, questions ...
My NVR is actually 7616N-E2/8P and it worked on that.
How much RAM does your NVR have?
I'm wondering if the 7608 models don't have the 500MB that the 7616 models have.
And do you have telnet or serial console access to see the RAM and CPU consumption?

Can you see motion events now as well as continuous on the web GUI Playback timeline?
 
Last edited by a moderator:
Top