- Mar 1, 2018
- 14
- 9
I purchased 12 cameras from Andy for a customer of mine. When I went to install at one location I was able to connect them and configure them as needed when sitting next to the Linksys LGS124P switch using a short CAT5E cable.
However, on all of my cable runs, which range from 50ft to 250ft, I get a link light on the switch but no activity light. I also cannot ping any of the cameras nor address them with the config tool. I even tried using a POE injector thinking that maybe I needed discrete power. It does the same thing, will power camera over short distance (I was using a 7ft CAT5E cable), but nothing on any of my cable runs.
I've tested the cable runs both with a cable tester as well as plugged my laptop into each run with success on both fronts.
The cable I have used is Southwire 24/4 CAT5E CMR riser off of a 1000ft spool I purchased at Home Depot. Here is a link to cable spec from manufacturer
I'm completely stumped here and don't know what my next step should be. I'm hoping that I don't have to cable the runs again as this is in a warehouse with 30 foot ceilings and I had to rent a scissor lift in order to run the cable in the first place.
Any ideas are welcomed.
FWIW I have 10 IPC-T5442T-ZE and 2 IPC-HFW5241E-Z12E cameras and I've also pinged Andy with this issue for his thoughts.
Thanks for any and all help on this.
However, on all of my cable runs, which range from 50ft to 250ft, I get a link light on the switch but no activity light. I also cannot ping any of the cameras nor address them with the config tool. I even tried using a POE injector thinking that maybe I needed discrete power. It does the same thing, will power camera over short distance (I was using a 7ft CAT5E cable), but nothing on any of my cable runs.
I've tested the cable runs both with a cable tester as well as plugged my laptop into each run with success on both fronts.
The cable I have used is Southwire 24/4 CAT5E CMR riser off of a 1000ft spool I purchased at Home Depot. Here is a link to cable spec from manufacturer
I'm completely stumped here and don't know what my next step should be. I'm hoping that I don't have to cable the runs again as this is in a warehouse with 30 foot ceilings and I had to rent a scissor lift in order to run the cable in the first place.
Any ideas are welcomed.
FWIW I have 10 IPC-T5442T-ZE and 2 IPC-HFW5241E-Z12E cameras and I've also pinged Andy with this issue for his thoughts.
Thanks for any and all help on this.
Last edited: