Recent content by Calvinder

  1. C

    Can't log into camera basic settings with ivms4200?

    Hello all I have been running this system for years. I run three cameras via wifi. Cams DS-2CD2041G1-IDW1 Firmware V5.5.82 build 190130 NVR Ds-7608ni-k2/8p Firmware Version: 4.30.005build200628 ivms4200 3.7.1.5 I recently moved and had to re configure the cameras for the new internet connection...
  2. C

    No audio from NVR only

    Hi Thomas thanks for your input. Yes I realize it has to go through an amp and it is. I have also checked the amp and it input. I should have said before it was working in the past. The reason I use it this way is it is running on an HDMI monitor that does not have speakers. This does however...
  3. C

    No audio from NVR only

    Hello everyone I have a Hikvision Ds-7608ni-k2/8p Firmware Version: 4.30.005build200628 and I get no audio at all out of the audio out RCA jack on the back. All audio settings I can find are on. I get audio with iVMS 4500 and iVMS 4200 both in live stream and playback. Any ideas? Thanks in...
  4. C

    Image cycles from clear to blurry about every two seconds. DS-2CD2041G1

    If OP is me yes I am using an NVR with up to date firmware.
  5. C

    Image cycles from clear to blurry about every two seconds. DS-2CD2041G1

    Another discovery It only does this if motion detection is enabled. If I watch live view or playback the video is fine. As soon as I enable motion detection it is bad. This is with all settings in factory mode. Edit: also it is bad only when the motion is in the selected areas.
  6. C

    Image cycles from clear to blurry about every two seconds. DS-2CD2041G1

    Wow thanks for that. Very interesting I had no idea about a couple of those points. But the thing I can't figure out is why does only this camera have this problem when all the cameras are set up identical. Even if I restore it to factory it runs fine for a wile then starts doing this again. Or...
  7. C

    Image cycles from clear to blurry about every two seconds. DS-2CD2041G1

    I beleve you are asking about the I Frame Interval it is 50 the same as the cameras that don't do this
  8. C

    Image cycles from clear to blurry about every two seconds. DS-2CD2041G1

    This is only on one of my DS-2CD2041G1-IDW1 cameras. It just started doing this with out any changes in the settings. All three cameras are configured exactly the same. I even imported settings. I have tried restoring it to factory settings with no luck. Some times if I try to fix it by changing...
  9. C

    Wireless mouse problems.

    Hi everyone I am trying to use a wireless mouse with my DS-7608NI-K2/8P NVR with firmware 4.30.005. The problem is if I go to the configuration page and hover over a box that is capable of entering numbers or text with out touching anything it immediately starts filling with V or O. I have tried...
  10. C

    One of my cameras will never go online.

    I figured it out It was a problem in the setting of the static ip in my router.
  11. C

    One of my cameras will never go online.

    Hello all I am having a problem getting one of my cameras to go online with Hik connect. All my other DS-2CD2041G1-IDW1 cameras are online. The one I am having problem with is on my network but will not connect to the internet. In addition it will not set its time by NTP. When I test, it...