Home assistant is very good with mqtt, actually native support for it. Same with blue iris and Synology got free and fully integrated components in home assistant
Read your posts. I live in Italy. Am using a DB1 with no chime installed, just the SAGE sensor integrated with my Hubitat Elevation (HE) hub. Configured the DB1 with the power-kit and the fuse (recommended if you have no chime), and configured the sw with electronic chime. It works fine. The only issue is that when there's a power outage in the area, and then power gets back, often the SAGE sensor keeps sending notifications as if someone rang the bell. In that case I simply remove its battery, wait 1 minute to let its capacitor discharge, and put the battery back on, no need to really reset it. It's the only issue I haven't manage to resolve but it doesn't happen every often luckily. I'm using latest hikvision firmware. I record everything with Synology Survellance Station on my DS1812+. I'm also using an Aeotec Siren 6 as internal chime, it's a z-wave device, I also use it as an alarm for various automation things, managed through HE.

Follow the connection schema in 101, but instead of the chime, picture the SAGE sensor, and add the fuse on the + of the transformer.

I'm using this AC 12-24V / 40VA transformer, a continuous service model, configured with 24V: Vemer VN320800 Trasformatore TMC 40/24 da Barra DIN per Servizio Continuo 230V/12-24V, Grigio Chiaro: Amazon.it: Fai da te

1594031371406.png
 

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
Read your posts. I live in Italy. Am using a DB1 with no chime installed, just the SAGE sensor integrated with my Hubitat Elevation (HE) hub. Configured the DB1 with the power-kit and the fuse (recommended if you have no chime), and configured the sw with electronic chime. It works fine. The only issue is that when there's a power outage in the area, and then power gets back, often the SAGE sensor keeps sending notifications as if someone rang the bell. In that case I simply remove its battery, wait 1 minute to let its capacitor discharge, and put the battery back on, no need to really reset it. It's the only issue I haven't manage to resolve but it doesn't happen every often luckily. I'm using latest hikvision firmware. I record everything with Synology Survellance Station on my DS1812+. I'm also using an Aeotec Siren 6 as internal chime, it's a z-wave device, I also use it as an alarm for various automation things, managed through HE.

Follow the connection schema in 101, but instead of the chime, picture the SAGE sensor, and add the fuse on the + of the transformer.

I'm using this AC 12-24V / 40VA transformer, a continuous service model, configured with 24V: Vemer VN320800 Trasformatore TMC 40/24 da Barra DIN per Servizio Continuo 230V/12-24V, Grigio Chiaro: Amazon.it: Fai da te

View attachment 65712
If you use DB1 without chime do you really need that beefy transformer? In the docs it say it should with no issues on 8V without a chime. How did you connect it? As usual, just attached the fuse inside the chime (disconnected the chime) and the sage how? since its not going to be connected to the chime?
 

alexdelprete

Getting comfortable
Joined
Jan 2, 2020
Messages
651
Reaction score
876
Location
Rome, Italy
If you use DB1 without chime do you really need that beefy transformer? In the docs it say it should with no issues on 8V without a chime. How did you connect it? As usual, just attached the fuse inside the chime (disconnected the chime) and the sage how? since its not going to be connected to the chime?
Not too beefy, and it's top quality, made in Italy, costs only a few € more than a cheap transformer, and these doorbells are very sensitive to power, plus I can attach also something else to it in the future, if needed. But don't go below 12V/24VA. Many problems in this thread were due to cheap 12V transformers.

Connection: like I told you, read the 101. You'll find this schema, instead of the chime you connect the SAGE.

1594039993869.png
 
Last edited:

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
so still use the power kit with sage, or the included fuse?

I have a ring transformer,but was hoping to get away with it as its not legal here to change it yourself, and I dont want to spend 300 usd for someone to change it
 

richtj99

Getting the hang of it
Joined
May 11, 2016
Messages
163
Reaction score
17
Hi - I am using the EZViz DB1 with Laview firmware flashed - 190716 is the build. I had it working & it lost Wifi. I downloaded the batch config tool & I only have an option to activate it, not add so I can configure wifi.

i seem to remember activating it was not a good thing so I am holding off for the moment. Am I doing something wrong or do i need an older version of batch config?
 

alexdelprete

Getting comfortable
Joined
Jan 2, 2020
Messages
651
Reaction score
876
Location
Rome, Italy
so still use the power kit with sage, or the included fuse?

I have a ring transformer,but was hoping to get away with it as its not legal here to change it yourself, and I dont want to spend 300 usd for someone to change it
Powerkit AND the fuse. Without powerkit it doesn't work. And since the fuse is recommended if you don't have a regular chime, you install both of them.

You can try the ring transformer and see how it goes, what kind of transfomer is it? Why is it illegal to replace a 12v transformer by yourself? What country do you live in?
 

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
Powerkit AND the fuse. Without powerkit it doesn't work. And since the fuse is recommended if you don't have a regular chime, you install both of them.

You can try the ring transformer and see how it goes, what kind of transfomer is it? Why is it illegal to replace a 12v transformer by yourself? What country do you live in?
Okay, so both I can install inside the chime I assume. I live in Norway, and its not legal to touch any electrical equipment. Since the transformer needs to be connected to 220V you need a professional to mount it or your house insurance will not be valid, plus you get a penalty requiring you to do a check of the whole house with professional agency.

Attached is a pic of the ring transformer. Not mine, but the same one


aHMPFnT.jpg
 

alexdelprete

Getting comfortable
Joined
Jan 2, 2020
Messages
651
Reaction score
876
Location
Rome, Italy
Okay, so both I can install inside the chime I assume. I live in Norway, and its not legal to touch any electrical equipment. Since the transformer needs to be connected to 220V you need a professional to mount it or your house insurance will not be valid, plus you get a penalty requiring you to do a check of the whole house with professional agency.

Attached is a pic of the ring transformer. Not mine, but the same one
If you use 1 and 4 (like in the pic) you'll have 24V 15VA. It should be enough. Try it. But...can you at least modify the wiring in Norway or is it still illegal? :)

I admire Norwegian people, you said no to EU and €. Great respect. :)
 
Last edited:

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
If you use 1 and 4 (like in the pic) you'll have 24V 15VA. It should be enough. Try it. But...can you at least modify the wiring in Norway or is it still illegal? :)

I admire Norwegian people, you said no to EU and €. Great respect. :)
I can do the doorbell side, but in norway you can not do anything on the 220v side, not change an outlet, change a fuse or anything like that. Its extremely strict
 

TechBill

Known around here
Joined
Nov 1, 2014
Messages
1,772
Reaction score
1,182
I can do the doorbell side, but in norway you can not do anything on the 220v side, not change an outlet, change a fuse or anything like that. Its extremely strict
The wires output on the transformer is not 220v. .. it's 8V to 24V which is actually the doorbell side ... but up to you on how you translate your laws
 

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
The wires output on the transformer is not 220v. .. it's 8V to 24V which is actually the doorbell side ... but up to you on how you translate your laws
But the input is 220v, so you cant put the transformer in. When its in place you can do the 24v side, but not put the unit in the electric cabinet
 

alexdelprete

Getting comfortable
Joined
Jan 2, 2020
Messages
651
Reaction score
876
Location
Rome, Italy
I can do the doorbell side, but in norway you can not do anything on the 220v side, not change an outlet, change a fuse or anything like that. Its extremely strict
I understand why. Everything must be compliant and certified, for safety reasons. It makes sense.

Anyway, you can use the ring transformer, I think it will work.
 

TechBill

Known around here
Joined
Nov 1, 2014
Messages
1,772
Reaction score
1,182
But the input is 220v, so you cant put the transformer in. When its in place you can do the 24v side, but not put the unit in the electric cabinet
Oh, I thought it was already in the electric breaker box and you only wanted to step up from 8v to 24v
 

alekslyse

Getting the hang of it
Joined
Dec 15, 2017
Messages
135
Reaction score
45
Oh, I thought it was already in the electric breaker box and you only wanted to step up from 8v to 24v
No, here in norway and europe "all" transformers are 8-12vac, so its almost always needed to be changed to a new one
 

alexdelprete

Getting comfortable
Joined
Jan 2, 2020
Messages
651
Reaction score
876
Location
Rome, Italy
No, here in norway and europe "all" transformers are 8-12vac, so its almost always needed to be changed to a new one
That's not true, I live in Italy, and we have transformers of any kind in use in all houses. Those are limits for your country probably.
 

TechBill

Known around here
Joined
Nov 1, 2014
Messages
1,772
Reaction score
1,182
After readubg some posts about transformer size
No, here in norway and europe "all" transformers are 8-12vac, so its almost always needed to be changed to a new one
Do you know the distance of your wiring from the doorbell to the transformer?

It will work on 12vac if the wiring is a short distance but the longer wiring then you will need to step up the voltage. Have you even tried it with 12vac yet?
 